Is distal femoral locking plate the implant of choice to fix all types of Distal femoral fractures?

Authors

  • Mian Amjad Ali Department of Orthopaedics, Lady Reading Hospital, Peshawar
  • Khurram Iqbal Department of Orthopaedics, Lady Reading Hospital, Peshawar
  • Faaiz Ali Shah Department of Orthopaedics, Lady Reading Hospital, Peshawar
  • Shams ur Rehman Department of Orthopaedics, Lady Reading Hospital, Peshawar
  • Syed Amjad Hussain Department of Orthopaedics, Lady Reading Hospital, Peshawar

Keywords:

Distal femoral fracture, locking plate, outcome.

Abstract

Objective: To determine the radiological and functional outcome of different types of distal femoral fractures fixed with locking plates.

Methods: This descriptive case series study was conducted at Department of Orthopaedic & Traumatology, Lady Reading Hospital Peshawar from February 2015 to June 2018. Patients of either gender or age with different types of distal femoral fractures fulfilling the inclusion criteria and fixed with distal femoral locking plates were enrolled into the study. Post-operative follow up visits were carried out at 4th week, 6th week and then monthly for 06 months and then every 3rd month till 02 years. Radiological and functional evaluation was done with modified Mize outcome criteria and graded as excellent, good, fair and failure.

Results: A total of 107 patients with mean age 44.57 ±SD12.03 years were operated with distal femoral locking plate. Only 6(5.6%) patients were lost to follow up and thus excluded from the study. Male patients were 68(67.3%) while female was 33(32.6%). Intra articular multifragmentary (33-C3) was the predominant fracture present in 29(28.7%) patients. Majority (n=85,8.1%) of the patients had excellent outcome as assessed with modified Mize outcome criteria while good outcome was achieved in 16(15.8%) patients. No non-union or implant failure was reported.

Conclusion: Distal femoral locking plates produced an excellent radiological and functional results in majority of the patients with different types of the distal femoral fractures. We recommend locking plate as an implant of first choice to fix all types of the distal femoral fractures.

References

1. Martinet O, Cordey J, Harder Y, Maier A, Buhler M, Barraud GE. The epidemiology of fractures of the distal femur. Injury. 2000 Sep;31( 3):62-3.
2. Reddy JAV, Chary NB. Functional Outcome of Distal End of Femur with Locking Compression Plate: A prospective study. Ann Int Med Den Res 2016;2(1):362-65.
3. Rajaiah D, Ramana Y, Srinivas K, Reddy SV. A study of surgical management of distal femoral fractures by distal femoral locking compression plate osteosynthesis. J Evid Based Med Healthc 2016; 3(66), 3584-3587.
4. Trivedi NP, Chauhan RH, Padhiyar DR, Gandhi SP. Outcome of fracture of intra articular distal femur treated with distal femur locking compression plate. Int J Res Orthop 2015 ;1(1):22-27.
5. Poole EC, Wilson GG, Guthrie HC, Bellringer SF, Freeman F, Guryel E et al. Modern distal femoral locking plates allow early weight bearing with a high rate of union and low rate of failure: Five year experience from a United Kingdom major trauma centre. Bone Joint J 2017 Jul;99-B:951–7.
6. Kayali C, Agus H, Turgut A. Successful results of minimally invasive surgery for comminuted supracondylar femoral fractures with LISS: comparative study of multiply injured and isolated femoral fractures. J Orthop Sci 2007 Sep;12:458-465.
7. Hartin NL, Harris I, Hazratwala K. Retrograde nailing versus fixed-angle blade plating for supracondylar femoral fractures: A randomized controlled trial. ANZ J Surg 2006 May;76(5):290-4.
8. Henderson CE, Kuhl, LL, Fitzparick DC, Marsh JL. Locking plates for distal femur fractures: Is there a problem with fracture healing? J Orthop. Trauma 2011 Feb;25 (1): 8-14.
9. Koval KJ, Hoehl JJ, Kummer FJ. Distal femoral fixation: a biomechanical comparison of the standard condylar buttress plate, a locked buttress plate and the 95-degree blade plate. J Orthop Trauma 1997 Oct;11:521–524.
10. Zlowodzki M, Cole PA, Williamson S. Biomechanical evaluation of the less invasive stabilization system, angled blade plate, and retrograde intramedullary nail for internal fixation of distal femur fractures. J Orthop Trauma 2004 Sep;18:494-502.
11. Greiwe RM, Archdeacon MT. Locking plate technology: Current concepts. J Knee Surg. 2007 Jan;20(1):50-5.
12. Heather V, Theresa H, John S. Failure of LCP condylar plate fixation in the distal part of the femur. J Bone Joint Surg. 2006 Apr;88-A:846-53.
13. Marsh JL, Slongo TF, Agel J, Broderick JS, Creevey W, DeCoster TA, et al. Fracture and dislocation classification compendium - 2007: Orthopaedic Trauma Association classification, database and outcomes committee. J Orthop Trauma 2007 Nov-Dec;21(10): 1-133.
14. Gustilo RB, Mendoza RM, Williams DN. Problems in the management of type III (severe) open fractures: A new classification of type III open fractures. J Trauma 1984 Aug;24:742-6.
15. Gupta RK, Rohilla RK, Sangwan K, Singh V, Walia S. Locking plate fixation in distal metaphyseal tibial fractures: Series of 79 patients. Int Orthop2010 Dec;34(8):1285–1290.
16. Rodriguez-Merchan EC, Gomez-Castresana F. Internal fixation of nonunions. Clin Orthop Relat Res 2004 Feb;419:13–20.
17. Mize RD, Bucholz RW, Grogan DP. Surgical treatment of displaced, comminuted fractures of the distal end of the femur. J Bone Joint Surg. Am 1982 Jul;64(6):871–9.
18. Gupta GK, Dr. Rani S, Kumar R, Singh B. Analysis of management of supracondylar femur fracture by locking compression plate. International Journal of Orthopaedics Sciences 2016 Sep;2(4): 218-222.
19. Saini RA, Shah N, Sharma D. Functional outcome of distal femoral fractures treated with DF-LCP [Distal femur locking compression plate]. International Journal of Orthopaedics Sciences 2018;4(1): 439-444.
20. Toro G, Calabrò G, Toro A, de Sire A, Lolascon G. Locking plate fixation of distal femoral fractures is a challenging technique: A retrospective review. Clin Cases Miner Bone Metab. 2015 Jan-Apr;12(Suppl 1):55-58.
21. Ricci WM, Streubel PN, Morshed S, Collinge CA, Nork SE, Gardner MJ. Risk factors for failure of locked plate fixation of distal femur fractures: An analysis of 335 cases. J Orthop Trauma. 2014 Feb;28(2):83-9.
22. Rodriguez EK, Boulton C, weaver MJ, Herder LM, Morgan JH, Chacko AT et al. Predictive factors of distal femoral fracture nonunion after lateral locked plating: A retrospective multicenter case-control study of 283 fractures. Injury 2014 Mar;45(3): 554-559.
23. Rodriguez EK, Zurakowski D, Herder L, Hall A, Walley KC, Weaver MJ et al. Mechanical construct characteristics predisposing to non-union after locked lateral plating of distal femur fractures. J Orthop Trauma 2016 Aug;30(8):403-8

Downloads

Published

2018-08-15

Conference Proceedings Volume

Section

Original Articles

How to Cite

Is distal femoral locking plate the implant of choice to fix all types of Distal femoral fractures?. (2018). Journal of Pakistan Orthopaedic Association, 30(02), 58-63. http://jpoa.org.pk/index.php/upload/article/view/207

Similar Articles

1-10 of 282

You may also start an advanced similarity search for this article.